LIST OF COMMON DEFICIENCIES
THIS LIST DOES NOT INCLUDE EVERYTHING AN INSPECTION MAY REVEAL AS DEFICIENT
SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS
-
SMOKE DETECTORS NOT INSTALLED IN REQUIRED LOCATIONS
-
SMOKE DETECTORS FAILED FUNCTION TEST
-
SMOKE DETECTORS HAVE EXPIRED
-
CARBON MONOXIDE DETECTORS NOT INSTALLED IN REQUIRED LOCATIONS
-
CARBON MONOXIDE DETECTORS FAILED FUNCTION TEST
-
CARBON MONOXIDE DETECTORS HAVE EXPIRED
DOORS AND WINDOWS
-
WEATHER STRIPPING ON DOOR DAMAGED OR MISSING
-
DOOR HANDLE LOOSE
-
DOOR HANDLE INSTALLED UPSIDE DOWN
-
DOOR LOCK DOES NOT FUNCTION PROPERLY
-
EGRESS DOOR REQUIRES KEY TO UNLOCK FROM INSIDE THE DWELLING
-
DOOR BINDS
-
DOOR OUT OF ALIGNMENT WITH ITS FRAME
-
LACK OF CAULKING AROUND DOORS
-
LACK OF CAULKING AROUND WINDOWS
-
WINDOW SCREEN MISSING
-
WINDOW SCREEN DAMAGED
-
WINDOW TOO HARD TO OPEN
-
WINDOW DOES NOT OPEN
-
WINDOW DOES NOT LATCH
-
WINDOW HAS LOST INSULATING PROPERTIES
-
WINDOW OPENING DOES NOT HAVE REQUIRED FALL PROTECTION
-
LACK OF SAFETY GLASS IN REQUIRED LOCATIONS
-
BURGLAR BARS REQUIRE KEY OR SPECIAL INSTRUCTION TO UNLOCK FROM INTERIOR
-
BASEMENT WINDOW WELL DOES NOT HAVE PERMANENT LADDER INSTALLED IN REQUIRED LOCATION
AUTOMATIC GARAGE DOOR
-
AUTOMATIC GARAGE DOOR FAILS TO RESPOND APPROPRIATELY TO OBJECTS
-
AUTOMATIC GARAGE DOOR HAS LOCK INSTALLED
-
INAPPROPRIATE USE OF EXTENSION CORD TO POWER AUTOMATIC GARAGE DOOR OPENER
GARAGE
-
GARAGE DOOR TO HOME DOES NOT MEET REQUIRED FIRE RATING
-
GARAGE FIRE RATING NOT INSTALLED OR MAINTAINED
-
ELECTRICAL CONNECTIONS INSTALLED TOO CLOSE TO GARAGE FLOOR
STAIRS
-
NO REQUIRED LIGHT INSTALLED FOR STAIRWAY
-
STAIRWAY LIGHT SWITCH IS NOT INSTALLED IN CORRECT LOCATION(S)
-
TREAD DEPTH INAPPROPRIATE FOR STAIRWAY TYPE
-
RISER HEIGHT INAPPROPRIATE FOR STAIRWAY TYPE
-
NO HANDRAIL INSTALLED FOR STAIRWAY
-
HANDRAIL NOT SECURELY MOUNTED
-
HANDRAIL DOES NOT TERMINATE APPROPRIATELY
-
HANDRAIL IS OF INAPPROPRIATE SIZE
-
HANDRAIL DOES NOT MEET THE MINIMUM OR MAXIMUM HEIGHT REQUIREMENTS
-
INCORRECT SPACING OF HANDRAIL BALUSTERS
-
INAPPROPRIATE HEIGHT OF OPEN RISERS ON STAIRWAY
GUARDRAILS
-
GUARDRAIL NOT INSTALLED IN REQUIRED LOCATION
-
GUARDRAIL NOT PROPERLY SECURED
-
GUARDRAIL DOES NOT MEET THE MINIMUM OR MAXIMUM HEIGHT REQUIREMENTS
-
INCORRECT SPACING OF GUARDRAIL BALUSTERS
KITCHEN
-
CAULK MISSING
-
GROUT MISSING
-
COUNTER TOP SURFACES ARE BROKEN
-
COUNTER TOP SURFACES ARE NOT SEALED
-
COUNTER TOP SURFACES ARE NOT SECURELY SUPPORTED
-
ABSORBENT SURFACES NOT PROTECTED
-
FIXTURE LOOSE
-
FIXTURE DOES NOT WORK
-
FIXTURE LEAKS
-
FIXTURE HAS HOT / COLD WATER REVERSED
-
DRAIN STOP MISSING
-
DRAIN STOP DOES NOT HOLD WATER
-
SINK SPRAY NOZZLE EXTENDS BELOW SINK RIM LEVEL AND WON'T SELF RETRACT ABOVE RIM LEVEL
-
SINK DISPOSAL IS NOT SECURELY MOUNTED
-
SINK DISPOSAL DOES NOT WORK
-
DISHWASHER NOT SECURELY MOUNTED
-
DISHWASHER DOES NOT WORK
-
DISHWASHER SOAP DOOR DOESN'T CLOSE
-
DISHWASHER DOES NOT HAVE BACK FLOW PREVENTION
-
DISHWASHER LEAKS
-
INAPPROPRIATE MATERIAL USED FOR RANGE VENT
-
COMBUSTIBLE MATERIALS TOO CLOSE TO RANGE
-
INAPPROPRIATE GAS CONNECTOR FOR RANGE
-
GAS LEAK AT RANGE
-
RANGE CONTROLS ARE NOT CHILD PROOF
-
RANGE DISPLAY DOES NOT WORK
-
INAPPROPRIATE GAS CONNECTOR FOR OVEN
-
GAS LEAK AT OVEN
-
OVEN TEMPERATURE DOES NOT MEET STANDARDS
BATHROOM
-
CAULK MISSING
-
GROUT MISSING
-
COUNTER TOP SURFACES ARE BROKEN
-
COUNTER TOP SURFACES ARE NOT SEALED
-
COUNTER TOP SURFACES ARE NOT SECURELY SUPPORTED
-
ABSORBENT SURFACES NOT PROTECTED
-
FIXTURE LOOSE
-
FIXTURE DOES NOT WORK
-
FIXTURE LEAKS
-
FIXTURE HAS HOT / COLD WATER REVERSED
-
DRAIN MISSING
-
DRAIN STOP DOES NOT HOLD WATER
-
SHOWER SPRAY HEAD EXTENDS BELOW TUB RIM LEVEL
-
TOILET CROSS CONNECTION
-
TOILET LEVEL TOO HIGH
-
TOILET NOT SECURELY MOUNTED
-
BATHROOM VENTILATION INADEQUATE
-
BATHROOM VENTILATION DOES NOT TERMINATE OUTSIDE
-
SAFETY GLASS NOT INSTALLED IN REQUIRED AREAS
-
GFCI OUTLETS NOT INSTALLED IN REQUIRED AREAS
-
UNABLE TO ACCESS HYDROTHERAPY TUB EQUIPMENT
-
HYDROTHERAPY TUB PUMP NOT BONDED
LAUNDRY ROOM
-
LAUNDRY VENT CLOGGED
-
LAUNDRY VENT WON'T SELF CLOSE
-
LAUNDRY VENT SCREENED
-
LACK OF GFCI OUTLETS IN REQUIRED LOCATION
INTERIOR MISC
-
INTERIOR FINISH IS DAMAGED
-
EVIDENCE OF SETTLEMENT OR EVIDENCE OF INCORRECT INSTALLATION OF INTERIOR FINISH (NAIL POPS OR DRYWALL TAPE EXPOSED)
-
EVIDENCE OF WATER PENETRATION
-
CABINETS AND / OR CABINET DOORS ARE NOT SECURELY MOUNTED
-
TRIP HAZARDS PRESENT
-
LACK OF SAFETY GLASS IN REQUIRED LOCATIONS
-
CLOSET LIGHTS INSTALLED IN INAPPROPRIATE LOCATION
-
CEILING FAN REQUIRES ADJUSTMENT / BALANCING
FIREPLACE
-
PERMANENT SCREEN NOT INSTALLED FOR FIREPLACE
-
COMBUSTIBLE MATERIALS INSTALLED TOO CLOSE TO FIREPLACE
-
NO DISCERNIBLE HEARTH EXTENSION FOR FIREPLACE
-
CRACKED REFRACTORY BRICK AND / OR MISSING MORTAR IN FIREPLACE
-
FABRICATED FIREPLACE DAMAGED
-
FIREPLACE DAMPER FAILS TO CLOSE PROPERLY
-
DAMPER CLAMP NOT INSTALLED ON GAS FUELED FIREPLACE
-
INAPPROPRIATE THICKNESS OF CREOSOTE PRESENT INSIDE CHIMNEY FLUE
-
LACK OF FIRE BLOCKING
-
CHIMNEY LEANING
-
NO SPARK ARRESTOR INSTALLED ON CHIMNEY
-
NO RAIN CAP INSTALLED ON CHIMNEY
GRADING AND DRAINAGE
-
GUTTER DOWN SPOUTS INCORRECTLY INSTALLED
-
INAPPROPRIATE DRAINAGE PROVIDED FOR FOUNDATION
-
EROSION OF SOIL AROUND HOUSE
-
LACK OF DRAINAGE TILES ON RETAINING WALLS
-
INAPPROPRIATE DRAINAGE TILE SIZE FOR RETAINING WALLS
-
INAPPROPRIATE DRAINAGE TILE SPACING FOR RETAINING WALLS
-
SOIL TOO CLOSE TO EXTERIOR SIDING
ROOF
-
MISSING / DAMAGED ROOF COVERINGS
-
DEBRIS LOCATED ON ROOF
-
CLADDING TOO CLOSE TO ROOF COVERING
-
ROOF FLASHING MISSING
-
ROOF FLASHING INSTALLED INCORRECTLY
-
ROOF FLASHING MATERIAL DAMAGED
-
ROOF FLASHING MATERIAL INAPPROPRIATE
-
NO BIRD STOPS INSTALLED ON TILE ROOFS
-
GUTTERS CONTAIN DEBRIS
EXTERIOR MISC
-
EXPOSED FOUNDATION REINFORCEMENT
-
VEGETATION TOUCHING HOUSE
-
MECHANICAL DAMAGE FROM VEGETATION OR OTHER OBJECT
-
SPALLING ON MASONRY CLADDING
-
NO WEEP SCREED ON STUUCO FINISH
-
ROTTEN WOOD
-
MISSING MORTAR
-
PAINT ON EXTERIOR
-
CAULKING
-
NO BACK FLOW PREVENTION INSTALLED ON HOSE BIB
-
HOSE BIB FAILS TO DELIVER WATER
-
EXTERIOR ELECTRICAL OUTLET COVERS INAPPROPRIATE
-
GAS APPLIANCE INSTALLED IN INAPPROPRIATE LOCATION
-
OPEN PIT FIREPLACE INSTALLED IN INAPPROPRIATE LOCATION
POOL / HOT TUB
-
POOL BARRIER DOES NOT MEET REQUIREMENTS
-
POOL GATE IS NOT SELF CLOSING AND SELF LATCHING
-
POOL GATE LATCHES ARE NOT AT THE REQUIRED HEIGHT
-
POOL GATE LATCHES ARE NOT CHILD RESISTANT
WATER HEATER (CONVENTIONAL / GAS)
-
WATER HEATER INSTALLED IN INAPPROPRIATE LOCATION
-
COMBUSTIBLES IN MECHANICAL CLOSET
-
FLEXIBLE GAS CONNECTOR INSTALLED THROUGH WALL
-
INCORRECT COLOR HANDLE ON GAS PIPE
-
NO SEDIMENT TRAP INSTALLED ON GAS HARD PIPE
-
INAPPROPRIATE MATERIAL USED FOR FLEXIBLE GAS CONNECTOR
-
COMBUSTION AIR FROM INAPPROPRIATE SOURCE
-
INAPPROPRIATE MATERIAL FOR FLUE VENT
-
NO DRAIN PAN INSTALLED IN REQUIRED LOCATION
-
VALVE LOCATED ON HOT WATER SUPPLY LINE
-
CORROSION PRESENT ON WATER LINES
-
SOLDERED CONNECTIONS ON WATER LINES
-
TPRV DISCHARGE PIPE DOES NOT TERMINATE IN APPROPRIATE LOCATION
-
TPRV DISCHARGE PIPE THREADED
-
TPRV DISCHARGE PIPE HAS VALVE INSTALLED
-
TPRV DISCHARGE PIPE NOT LARGE ENOUGH DIAMETER
ELECTRICAL
-
BROKEN OUTLETS
-
OUTLETS ARE PAINTED
-
BROKEN OUTLET COVERS
-
MISSING OUTLET COVERS
-
POLARITY REVERSED ON OUTLETS
-
OUTLETS UNGROUNDED
-
LACK OF GFCI PROTECTED OUTLETS IN REQUIRED LOCATIONS
-
LACK OF AFCI PROTECTED OUTLETS IN REQUIRED LOCATIONS
-
CEILING FANS OUT-OF-BALANCE
-
NO ISOLATING LINKS ON CEILING FANS
-
INAPPROPRIATE SWITCH USED FOR CEILING FAN
-
INAPPROPRIATE USE OF EXTENSION CORDS
-
BURNED OUT LIGHTBULBS
-
UNPROTECTED LIGHT BULBS
-
DOOR BELL FAILS TO OPERATE
-
ELECTRICAL SERVICE DANGEROUS
-
ELECTRICAL SERVICE CLEARANCES
-
NEUTRAL WIRES DOUBLE TAPPED IN SERVICE PANEL
-
NEUTRAL AND GROUND WIRES COMINGLED ON SAME BUS
-
INAPPROPRIATE COMBINATION OF WIRE SIZE, CIRCUIT BREAKER, AND /OR OUTLET TYPE
-
INAPPROPRIATE CONNECTIONS ALUMINUM WIRING
-
INAPPROPRITE OUTLET USED FOR ALUMINUM WIRING
-
LACK OF BOND ON CSST PIPING
-
OPEN CONNECTIONS
-
INSULATION CLEARANCES FOR RECESSED LIGHTS
-
LIGHT FIXTURES TOO CLOSE TO CLOSET SHELVING
-
IMPROPER, OR LACK OF, SUPPORT FOR WIRES
HVAC (GAS FURNACE & ELECTRIC AC)
-
GAS FURNACE INSTALLED IN INAPPROPRIATE LOCATION
-
COMBUSTIBLES IN MECHANICAL CLOSET
-
FLEXIBLE GAS CONNECTOR INSTALLED THROUGH WALL
-
INCORRECT COLOR HANDLE ON GAS PIPE
-
NO SEDIMENT TRAP INSTALLED ON GAS HARD PIPE
-
INAPPROPRIATE MATERIAL USED FOR FLEXIBLE GAS CONNECTOR
-
COMBUSTION AIR FROM INAPPROPRIATE SOURCE
-
INAPPROPRIATE MATERIAL FOR FLUE VENT
-
AIR FILTER DIRTY
-
DIRTY AIR REGISTERS
-
MAIN CONDENSATE DRAIN NOT TRAPPED
-
MAIN CONDENSATE DRAIN DISCHARGES TO INAPPROPRIATE RECEPTOR
-
WATER PRESENT IN AUXILIARY DRAIN PAN
-
AUXILIARY DRAIN PAN HAS RUST
-
AUXILIARY DRAIN PAN DISCHARGES TO INAPPROPRIATE RECEPTOR
-
CONDENSER COIL NOT LEVEL
-
CONDENSER COIL FINS DAMAGED
-
INSULATION MISSING ON SUCTION LINE
-
HVAC INSTALLED IN INAPPROPRIATE LOCATION
-
CLOTHES DRYER VENT TOO CLOSE
-
INAPPROPRIATE MATERIAL SUPPORTING DUCTS